{"title":"Fuses (marine, RV, caravan)","description":"","products":[{"product_id":"187-series-circuit-breaker-panel-mount-25a","title":"187-Series Circuit Breaker - Panel Mount 25A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630389051567,"sku":"","price":104.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7035.jpg?v=1619084072"},{"product_id":"187-series-circuit-breaker-panel-mount-30a","title":"187-Series Circuit Breaker - Panel Mount 30A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630392787119,"sku":"","price":104.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7036.jpg?v=1619084154"},{"product_id":"187-series-circuit-breaker-panel-mount-40a","title":"187-Series Circuit Breaker - Panel Mount 40A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630405238959,"sku":"","price":104.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7038.jpg?v=1619084238"},{"product_id":"187-series-circuit-breaker-panel-mount-50a","title":"187-Series Circuit Breaker - Panel Mount 50A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630421262511,"sku":"","price":104.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7039.jpg?v=1619084403"},{"product_id":"187-series-circuit-breaker-panel-mount-60a","title":"187-Series Circuit Breaker - Panel Mount 60A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630427160751,"sku":"","price":109.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7040.jpg?v=1619085088"},{"product_id":"187-series-circuit-breaker-panel-mount-70a","title":"187-Series Circuit Breaker - Panel Mount 70A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630431846575,"sku":"","price":109.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7041.jpg?v=1619084613"},{"product_id":"187-series-circuit-breaker-panel-mount-80a","title":"187-Series Circuit Breaker - Panel Mount 80A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630438105263,"sku":"","price":114.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7042.jpg?v=1619084693"},{"product_id":"187-series-circuit-breaker-panel-mount-90a","title":"187-Series Circuit Breaker - Panel Mount 90A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630440923311,"sku":"","price":119.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7043.jpg?v=1619084731"},{"product_id":"187-series-circuit-breaker-panel-mount-100a","title":"187-Series Circuit Breaker - Panel Mount 100A","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630445183151,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7044.jpg?v=1619084793"},{"product_id":"187-series-circuit-breaker-panel-mount-120a","title":"187-Series Circuit Breaker - Panel Mount 120A","description":"\u003cp\u003e\u003cstrong\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630447476911,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7046.jpg?v=1619084827"},{"product_id":"187-series-circuit-breaker-panel-mount-135a","title":"187-Series Circuit Breaker - Panel Mount 135A","description":"\u003cp\u003e\u003cstrong\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630453407919,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7047.jpg?v=1619084912"},{"product_id":"187-series-circuit-breaker-panel-mount-150a","title":"187-Series Circuit Breaker - Panel Mount 150A","description":"\u003cp\u003e\u003cstrong\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\n","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630454620335,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7048.jpg?v=1619084943"},{"product_id":"187-series-circuit-breaker-panel-mount-200a","title":"187-Series Circuit Breaker - Panel Mount 200A","description":"\u003cp\u003e\u003cstrong\u003eThermal circuit breakers provide heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit protection into a single device\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClear, single lever operation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" design cannot be held \"ON\" during fault current condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWaterproof\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRecessed mounting holes for clean appearance\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Clearance around terminal studs accept heavy gauge wire lugs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRobust 5\/16 M8 terminals provide high torque connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge lever with vertical\/horizontal orientation provides indication of trip status\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630456160431,"sku":"","price":139.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7049.jpg?v=1619084982"},{"product_id":"285-series-circuit-breaker-panel-mount-25a","title":"285-Series Circuit Breaker - Panel Mount 25A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e25A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003ePanel Mount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39630933557423,"sku":"","price":109.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7080.jpg?v=1619090599"},{"product_id":"285-series-circuit-breaker-panel-mount-30a","title":"285-Series Circuit Breaker - Panel Mount 30A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e25A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003ePanel Mount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631001747631,"sku":"","price":109.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7081.jpg?v=1619091013"},{"product_id":"285-series-circuit-breaker-panel-mount-40a","title":"285-Series Circuit Breaker - Panel Mount 40A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable id=\"specifications\" class=\"product_table masonry-brick\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 16px;\"\u003e\n\u003cth colspan=\"2\" style=\"height: 16px; text-align: left;\"\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\" id=\"51\" style=\"height: 16px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 16px; text-align: left;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 16px; text-align: left;\"\u003e40A\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\" id=\"174\" style=\"height: 16px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 16px;\"\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 16px;\"\u003e48V DC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\" id=\"256\" style=\"height: 16px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 16px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 16px;\"\u003ePanel Mount\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\" id=\"27\" style=\"height: 16px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 16px;\"\u003e\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 16px;\"\u003eThermally responsive Bi-metal blade\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\" id=\"138\" style=\"height: 16px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 16px;\"\u003e\u003cstrong\u003eTerminal Stud\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 16px;\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\" id=\"8\" style=\"height: 16px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 16px;\"\u003e\u003cstrong\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 16px;\"\u003e50 in-lb (5.65 Nm)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\" id=\"239\" style=\"height: 16px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 16px;\"\u003e\u003cstrong\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 16px;\"\u003e3000A @ 48V\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\" id=\"290\" style=\"height: 35px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 35px;\"\u003e\u003cstrong\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 35px;\"\u003e-40° C\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\" id=\"291\" style=\"height: 35px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 35px;\"\u003e\u003cstrong\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 35px;\"\u003e85° C\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\" id=\"137\" style=\"height: 35px;\"\u003e\n\u003ctd class=\"spec_title\" style=\"height: 35px;\"\u003e\u003cstrong\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\" style=\"height: 35px;\"\u003eType III - switchable\/manual reset - trip free\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\" id=\"16\"\u003e\n\u003ctd class=\"spec_title\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"spec_value\"\u003e0.50lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631017967791,"sku":"","price":109.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7082.jpg?v=1619091154"},{"product_id":"285-series-circuit-breaker-panel-mount-50a","title":"285-Series Circuit Breaker - Panel Mount 50A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003ePanel Mount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631047917743,"sku":"","price":109.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7083.jpg?v=1619091749"},{"product_id":"285-series-circuit-breaker-panel-mount-60a","title":"285-Series Circuit Breaker - Panel Mount 60A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e60A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePanel Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631065350319,"sku":"","price":114.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7084.jpg?v=1619092003"},{"product_id":"285-series-circuit-breaker-panel-mount-70a","title":"285-Series Circuit Breaker - Panel Mount 70A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e70A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePanel Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631066661039,"sku":"","price":114.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7085.jpg?v=1619091842"},{"product_id":"285-series-circuit-breaker-panel-mount-80a","title":"285-Series Circuit Breaker - Panel Mount 80A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e80A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePanel Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631069479087,"sku":"","price":119.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7086.jpg?v=1619091924"},{"product_id":"285-series-circuit-breaker-panel-mount-100a","title":"285-Series Circuit Breaker - Panel Mount 100A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e100A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePanel Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631075606703,"sku":"","price":84.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7087.jpg?v=1619092085"},{"product_id":"285-series-circuit-breaker-panel-mount-120a","title":"285-Series Circuit Breaker - Panel Mount 120A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e120A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePanel Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631077081263,"sku":"","price":84.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7088.jpg?v=1619092146"},{"product_id":"285-series-circuit-breaker-panel-mount-150a","title":"285-Series Circuit Breaker - Panel Mount 150A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e150A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePanel Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003e50 in-lb (5.65 Nm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631082225839,"sku":"","price":84.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7089.jpg?v=1619092188"},{"product_id":"285-series-circuit-breaker-surface-mount-25a","title":"285-Series Circuit Breaker - Surface Mount 25A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e25A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e60 in-lb (6.78 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631098413231,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7180.jpg?v=1619092488"},{"product_id":"285-series-circuit-breaker-surface-mount-30a","title":"285-Series Circuit Breaker - Surface Mount 30A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e30A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631132786863,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7181.jpg?v=1619092856"},{"product_id":"285-series-circuit-breaker-surface-mount-40a","title":"285-Series Circuit Breaker - Surface Mount 40A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e40A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631142420655,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7182.jpg?v=1619092955"},{"product_id":"285-series-circuit-breaker-surface-mount-50a","title":"285-Series Circuit Breaker - Surface Mount 50A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631145762991,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7183.jpg?v=1619093037"},{"product_id":"285-series-circuit-breaker-surface-mount-60a","title":"285-Series Circuit Breaker - Surface Mount 60A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e60A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631149301935,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7184.jpg?v=1619093092"},{"product_id":"285-series-circuit-breaker-surface-mount-70a","title":"285-Series Circuit Breaker - Surface Mount 70A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e70A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631154479279,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7185.jpg?v=1619093170"},{"product_id":"285-series-circuit-breaker-surface-mount-80a","title":"285-Series Circuit Breaker - Surface Mount 80A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e80A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631165292719,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7186.jpg?v=1619093306"},{"product_id":"285-series-circuit-breaker-surface-mount-100a","title":"285-Series Circuit Breaker - Surface Mount 100A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e100A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631169880239,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7187.jpg?v=1619093410"},{"product_id":"285-series-circuit-breaker-surface-mount-120a","title":"285-Series Circuit Breaker - Surface Mount 120A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e120A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631174533295,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7188.jpg?v=1619093445"},{"product_id":"285-series-circuit-breaker-surface-mount-150a","title":"285-Series Circuit Breaker - Surface Mount 150A","description":"\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrop in replacement for 185-Series Circuit Breakers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVisible reset lever shows open condition\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIgnition protected - Safe for installation aboard gasoline powered boats\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets SAE J1171 external ignition protection requirements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeather Resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombines switching and circuit breaker function into one unit*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\"Trip Free\" - cannot be held closed after trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not use as a switch where high inrush currents are expected\u003c\/p\u003e\n\u003ch4\u003eMeets the following Regulatory Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIgnition Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSAI J171 Marine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"340\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmperage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e150A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e48V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSurface Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThermally responsive Bi-metal blade\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e50 in-lb (5.65 Nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInterrupt Capacity \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3000A @ 48V \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-40° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e85° C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCircuit Breaker Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eType III - switchable\/manual reset - trip free\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTerminal Stud\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eM6 (accepts 1\/4\" Ring Terminal)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.50lb (0.23 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631175712943,"sku":"","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7189.jpg?v=1619093506"},{"product_id":"360-panel-mount","title":"360 Panel Mount","description":"\u003cp\u003eUse with 285-Series or 185-Series Panel Mount Circuit Breakers\u003c\/p\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ctable class=\"product_table masonry-brick\" id=\"specifications\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" colspan=\"2\"\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"16\" class=\"even\"\u003e\n\u003ctd class=\"spec_title\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"spec_value\"\u003e0.72lb (0.33 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631190818991,"sku":"","price":17.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/1477.jpg?v=1619093789"},{"product_id":"285-series-circuit-breaker-bezel-mount-adapter","title":"285-Series Circuit Breaker Bezel Mount Adapter","description":"\u003cul\u003e\n\u003cli\u003eBezel mounting allows circuit breaker mounting in a 2-1\/8 ″ round hole\u003c\/li\u003e\n\u003cli\u003eUse with 285-Series or 185-Series Panel Mount Circuit Breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ctable class=\"product_table masonry-brick\" id=\"specifications\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" colspan=\"2\"\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"16\" class=\"even\"\u003e\n\u003ctd class=\"spec_title\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"spec_value\"\u003e0.50lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631203369135,"sku":"","price":15.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7098.jpg?v=1619093938"},{"product_id":"285-series-circuit-breaker-panel-mount-adapter","title":"285-Series Circuit Breaker Panel Mount Adapter","description":"\u003cul\u003e\n\u003cli\u003eSelf trimming molded rubber bezel\u003c\/li\u003e\n\u003cli\u003eUse with 285-Series or 185-Series Panel Mount Circuit Breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ctable class=\"product_table masonry-brick\" id=\"specifications\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" colspan=\"2\"\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"16\" class=\"even\"\u003e\n\u003ctd class=\"spec_title\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"spec_value\"\u003e0.04lb (0.02 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BlueSea Systems","offers":[{"title":"Default Title","offer_id":39631208808623,"sku":"","price":15.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0278\/5666\/6701\/products\/7198.jpg?v=1619093995"}],"url":"https:\/\/smarthybridenergy.myshopify.com\/fi\/collections\/fuses-marine-rv-caravan.oembed?page=2","provider":"FinnAmps","version":"1.0","type":"link"}